Item No. DSS 07
DESCO Digital Hb Reader
- This Hb reader is designed on "Cyanmethaemoglobin method "& keeping in view to make the analysis simpler.
- The cumbersome step of calculation is deleted while using this Hb Reader.
- The final result of the unknown test will be displayed directly in conc. (gm/dl).
- There is no need of calculations. However O.D. switch is also given in case of optical density is required to cross check the reading .
- A micro controller has been incorporated in the system for accuracy & reproducibility of findings.
- This Hb Reader is a compact, elegant, very reliable micro controller based equipment to produce accurate results.
- This Hb reader has been designed to operate in the following two modes.
- (A) STD mode (concentration of 15 gm/ dl has been fed) (B) NON STD mode (Absorbence of 0.30 (O.D) has been fed).
- In case, the CONC.or ABS.of STD is different form 15 gm/dl or 0.30 respectively, the user can feed the required values with the help of switch no.3&4 given on the KEYPAD on front panel)
Technical Specifications
- Wave length Filter: - 546 ± 10 nm glass filter
-
Minimum volume: -1m
-
Display: -2 ½ digits seven segment display for Conc./ABS. measurement
-
Indicator: -5 mm LED indicators provided for different modes
-
Light Source: -6v, 10w Tungsten Lamp
-
Detector: Silicon photo diode
-
Input supply: -Mains: 220 ± 10%, 50Hz, 1Ø Battery: 12V DC
-
Dimentions: 12'x11.5'x6.25'
-
Test Tubes: Square 10x10 mm (plastic)
-
Weight:-5Kg Approx.Net
|
|
|